Low-Cost Ways to Improve Data Centre Airflow management.

With higher-density loads generating more heat in data centre's, having an up-to-date cooling strategy to cool equipment efficiently is essential. Problem is, many data centre managers are not aware of the biggest culprits behind data centre cooling in-efficiency.

  • Poor or no airflow management.
  • Redundant Cabling.
  • Un-sealed cutouts in floor tiles.
  • Un-used U space within cabinets.

Fortunately, Phoenix Optics offer simple cost-effective green solutions for addressing these challenges.

PlenaForm® Airflow Management System.

PlenaForm® is a flexible, air flow management system, that fits under Data Centre raised floors and helps to solve dynamic thermal imbalances within the data centre. Used to create dedicated "hot and cold aisles" under the raised floor, PlenaForm® increases the static pressure, delivering a higher volume of cooling directly to the cold aisle's perforated tiles reducing the workload of the CRAC units.

If a section of the data centre is unused, there is no need to pump air to it under the floor. Our engineers can install under-floor barriers to direct the air flow only to areas where it is required.

under floor air flow management data centre cooling

HotLok® blanking panels.

HotLok® Blanking Panels provide a 99%+ effective seal for both 1U and 2U openings in IT equipment cabinets, The panels help control hotspots and bypass airflow for optimized cooling effectiveness by preventing hot exhaust air or hot-aisle air from migrating to the air-intake stream at the front of the cabinet. Depending on placement in the cabinet, HotLok Blanking Panels help deliver more cool air to the upper one-third of the cabinet, which is typically the hottest section and most prone to hotspots and equipment reliability problems.

The energy-efficient cantilevered sealing vanes eliminate the gap between adjoining HotLok Blanking Panels or with installed equipment, providing a snug seal and no air leaks.

All HotLok® Blanking Panels are fire-retardant, made of 100 percent recyclable ABS plastic, and RoHS compliant.

KoldLok® Raised floor Grommets

KoldLok offer a range of specially designed raised-floor grommets designed to seal cutouts within the raised-floor and stop cold air from escaping, whilst still allowing cables to pass through. The KoldLok raised-floor grommets are static disappative and prevent static discharges being carried up the cables. By sealing cutouts within the raised-floor, cooling the data centre environment is drastically improved.

The Koldlok raised floor grommets products are available in a variety of sizes and are designed to fit into both new and existing cut outs.

  • Increases existing cooling unit capacity
  • Reduces the need to purchase additional cooling units
  • Improves equipment reliability and extends equipment life
  • Increases static pressure under the raised floor and improves cool air delivery through perforated tiles and floor grates
  • Facilitates Cold Aisle / Hot Aisle best practices